<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Automatic grease pump &#8211; JINPINLUB</title>
	<atom:link href="https://www.jinpinlub.com/product-tag/automatic-grease-pump/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.jinpinlub.com</link>
	<description>Lubrication system solution provider</description>
	<lastBuildDate>Wed, 11 Dec 2024 21:41:01 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.jinpinlub.com/wp-content/uploads/2024/08/JINPINLUB-100x100.png</url>
	<title>Automatic grease pump &#8211; JINPINLUB</title>
	<link>https://www.jinpinlub.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>J100-7C 24VDC Electric Automatic Grease Lubrication Pumps</title>
		<link>https://www.jinpinlub.com/product/j100-7c-24vdc-electric-automatic-grease-lubrication-pumps/</link>
		
		<dc:creator><![CDATA[JINPINLUB]]></dc:creator>
		<pubDate>Wed, 11 Dec 2024 21:23:20 +0000</pubDate>
				<guid isPermaLink="false">https://www.jinpinlub.com/?post_type=product&#038;p=4008</guid>

					<description><![CDATA[The J100 series electric piston pump unit is a device for single-line centralized lubrication systems, featuring compact design, quick replacement of lubricant cartridges, dual outlet lubricant delivery, automatic control system and precise output lubricant.]]></description>
										<content:encoded><![CDATA[<h2>Features</h2>
<p>&#8211; Electric drive: The electric motor drives the piston pump unit of the J100 lubrication pump, and via an eccentric, it drives the delivery piston in the axial direction.<br />
&#8211; Lubricant delivery: The delivery piston pushes the lubricant from the lubricant cartridge or oil reservoir of the lubrication pump via an internal control valve to the lubricant outlet.<br />
&#8211; Pressure relief: Following the lubrication cycle, on switching off the lubrication pump motor, a pressure relief valve releases the system pressure required by single-line metering devices.<br />
&#8211; Pressure limitation: The integrated pressure limiting valve limits the maximum system pressure of the centralized lubrication system to 80 bar.<br />
&#8211; Lubricant supply: The lubricant can be supplied via a disposable lubricant cartridge or oil reservoir.<br />
&#8211; Fill level monitoring: The J100 lubrication pump can be optionally fitted with a fill level switch to monitor the minimum fill level.</p>
<h2>Specification</h2>
<table>
<tbody>
<tr>
<td>Model</td>
<td>J100-3C</td>
</tr>
<tr>
<td>Lubrication time</td>
<td>PLC or external controller</td>
</tr>
<tr>
<td>Interval time</td>
<td>PLC or external controller</td>
</tr>
<tr>
<td>Operating temperature</td>
<td>0℃~ +50°C (Low temperature conditions require antifreeze grease)</td>
</tr>
<tr>
<td>Number of outlets</td>
<td>1 or 2</td>
</tr>
<tr>
<td>Reservoir capacity</td>
<td>0.3L, 0.5L, 0.7L, 1.5L</td>
</tr>
<tr>
<td>Refilling</td>
<td>Filling port/removable/cartridge</td>
</tr>
<tr>
<td>Lubricant</td>
<td>NLGI 000#~2#</td>
</tr>
<tr>
<td>Pressure relief valve</td>
<td>Optional</td>
</tr>
<tr>
<td>Discharge</td>
<td>15 mL/min</td>
</tr>
<tr>
<td>Max. operating pressure</td>
<td>8.0 MPa</td>
</tr>
<tr>
<td>Connection thread</td>
<td>Outlet Φ6</td>
</tr>
<tr>
<td>Operating voltage</td>
<td>24VDC</td>
</tr>
<tr>
<td>Certification</td>
<td>CE</td>
</tr>
<tr>
<td>Low level switch</td>
<td>N.C. contact</td>
</tr>
</tbody>
</table>
<h2>Maintenance</h2>
<p>&#8211; Check lubricant levels: Check regularly based on number of pump cycles and setup of system.<br />
&#8211; System leak check: A check for leaks in system components during every fill of pump and fix those found immediately.<br />
&#8211; Electrical Safety: The cables of the electric lubrication pump should be inspected on a regular basis for any damages. All electrical work, such as repair and modification, shall be performed by a qualified technician after power removal.<br />
&#8211; Cleaning and contamination prevention: Use a compatible cleaning agent to avoid contamination of the J100 lubrication pump.<br />
&#8211; Follow safe procedures: Before starting any maintenance, cleaning, or repairs on the pump, ensure the following safety measures are strictly followed: removal of power, depressurization, locking/tagging equipment, and personal protective equipment.</p>