<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Dual-line metering valve &#8211; JINPINLUB</title>
	<atom:link href="https://www.jinpinlub.com/product-tag/dual-line-metering-valve/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.jinpinlub.com</link>
	<description>Lubrication system solution provider</description>
	<lastBuildDate>Fri, 13 Sep 2024 16:24:20 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.jinpinlub.com/wp-content/uploads/2024/08/JINPINLUB-100x100.png</url>
	<title>Dual-line metering valve &#8211; JINPINLUB</title>
	<link>https://www.jinpinlub.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>ZV-B Dual Line Distributor For Dual-Line Lubrication System</title>
		<link>https://www.jinpinlub.com/product/zv-b-dual-line-distributor-for-dual-line-lubrication-system/</link>
		
		<dc:creator><![CDATA[JINPINLUB]]></dc:creator>
		<pubDate>Fri, 13 Sep 2024 16:12:37 +0000</pubDate>
				<guid isPermaLink="false">https://www.jinpinlub.com/?post_type=product&#038;p=3685</guid>

					<description><![CDATA[The ZV-B distributor is used in dual-line central lubrication systems and is suitable for oil and grease. It meters and delivers lubricants to the lubrication points independently of back pressure. Features include up to 8 outlets, metering volumes from 0.5 to 3.0 ml/cycle.]]></description>
										<content:encoded><![CDATA[<h2>Feature</h2>
<p>The ZVB dual wire distributor is suitable for 40MPa grease or oil dual line lubrication systems. The distributor can be installed with three options: Metering screw, Adjusting device, and Motion indicator.<br />
1. For ZVB with Metering shrews, the Metered volume cannot be adjusted. Only by selecting different index Metering shrews can the Metered volume be changed.<br />
2. ZVB with Adjusting device, Metered volume can be adjusted from zero to rated range, and can judge whether distributor is working properly by observing the Adjusting device.<br />
3. ZVB with motion indicator can adjust the metered volume within the range of zero to rated range, and can control the metered volume by sending a signal through the monitoring switch. Each distributor can only come with one adjustment device.</p>
<h2>Specification</h2>
<table>
<tbody>
<tr>
<td>Model</td>
<td>ZV-B</td>
</tr>
<tr>
<td>Operating pressure</td>
<td>40 MPa</td>
</tr>
<tr>
<td>Action pressure</td>
<td>≤1.0 MPa</td>
</tr>
<tr>
<td>Piston output</td>
<td>0.3mL</td>
</tr>
<tr>
<td>Discharge</td>
<td>0.5, 1.5, 3.0mL/cycle</td>
</tr>
<tr>
<td>Number of outlets</td>
<td>2~8</td>
</tr>
<tr>
<td>Lubricant</td>
<td>Grease NLGI 0~3# or Oil ＞ N68</td>
</tr>
<tr>
<td>Operating temperature</td>
<td>(-20 ℃ ~ 80 ℃)</td>
</tr>
</tbody>
</table>
<h2>Instruction</h2>
<p>1. When used in dusty, humid and harsh environment, it should be equipped with protective cover.<br />
2. The parallel installation method is preferred in the dual-wire system. Secondly, the series installation method is adopted, and the two G3/8 plugs at the inlet on one side must be removed. The maximum number of serial connections is not allowed to exceed two, and can be installed in parallel and series if necessary.<br />
3. The ZVB-S, Metered volume with Metering screw can not be adjusted, only the Metering screw with different index can be selected to change the Metering screw.<br />
4. For the ZVB-M with Adjusting device, the adjustment of the Metered volume should rotate the adjusting screw of the limiter when the rod is retracted.<br />
5. For ZVB-L with motion indicator, adjustment of Metered volume should be carried out when indicator lever is retracted.<br />
6. If the number of outlets needs to be odd, remove the screws between the corresponding outlets and block the outlet that is not in use with G1/4 &#8220;plugs. The upper and lower outlets are connected, and both the forward and reverse movements of the piston are discharged from this outlet.<br />
7. For ease of disassembly, it is best to bend the pipeline from ZVB to lubrication points at a 90 ° angle or use a sleeve joint.<br />
8. The installation surface of the distributor should be smooth and flat, and the installation bolts should not be tightened too tightly to avoid deformation and affecting normal operation during use.<br />
9. It is recommended to use GB70-85 screws M60 x 50 for installation and fixation of ZVB-S and ZVB-M. A 30mm base plate should be provided between the installation surfaces of ZVB-L, and GB70-85 special screws M6 x 85 should be used for installation and fixation.</p>
<h2>Manuals</h2>
<div class="sdm_download_button_box_default"><div class="sdm_download_link"><a href="https://www.jinpinlub.com/?sdm_process_download=1&download_id=3665" class="sdm_download white" title="Private: ZVB Distributor" target=&quot;_blank&quot;>View Datasheet - ZVB Distributor</a></div></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Galvanized Steel VSL Metering Devices For Dual-Line System</title>
		<link>https://www.jinpinlub.com/product/galvanized-steel-vsl-metering-devices-for-dual-line-system/</link>
		
		<dc:creator><![CDATA[JINPINLUB]]></dc:creator>
		<pubDate>Fri, 13 Sep 2024 15:58:47 +0000</pubDate>
				<guid isPermaLink="false">https://www.jinpinlub.com/?post_type=product&#038;p=3681</guid>

					<description><![CDATA[The VSL series metering devices are designed for dual line lubrication systems and can handle pressures up to 400 bar. Made from durable galvanised steel, they can be fitted with up to eight outlets, each with an indicator pin for visual monitoring.]]></description>
										<content:encoded><![CDATA[<h2>Feature</h2>
<p>There are outlets on both the top and bottom of the VSL-KR, and when the distributor piston moves forward and backward, grease is discharged from the outlets on both sides. There is a combined discharge structure in the corresponding upper and lower outlets. To change the odd number of outlets, simply unscrew the screws in the holes. The operation of the distributor can also be directly observed from the action of the indicator rod, and the discharge of each outlet can be adjusted by adjusting the screws. This type of distributor is used under the alternating supply pressure of two main supply pipes, and the piston action is directly controlled by the supply pressure.</p>
<h2>Specification</h2>
<table>
<tbody>
<tr>
<td>Model</td>
<td>VSL-KR</td>
</tr>
<tr>
<td>Operating pressure</td>
<td>40 MPa</td>
</tr>
<tr>
<td>Action pressure</td>
<td>≤1.0 MPa</td>
</tr>
<tr>
<td>Rated discharge</td>
<td>0~5 mL/cyc</td>
</tr>
<tr>
<td>Adjusting screw flow</td>
<td>0.15mL/circle</td>
</tr>
<tr>
<td>Number of outlets</td>
<td>2~8</td>
</tr>
<tr>
<td>Lubricant</td>
<td>Grease NLGI 0~2# or Oil ＞ N68</td>
</tr>
<tr>
<td>Operating temperature</td>
<td>(-10 ℃ ~ 80 ℃)</td>
</tr>
</tbody>
</table>
<h2>Instruction</h2>
<p>If it is necessary to merge the corresponding upper and lower outlets, simply unscrew the pressure plug in the upper oil outlet hole with a 6mm hex wrench, remove the oil distribution sleeve through hole and install it downwards, then tighten the pressure plug, the upper outlet is blocked with a G14 plug to prevent dust. Distributors used outside the range of -10 ℃ to 80 ℃ must be specified in the purchase in order to provide low and high temperature resistant oil seals during supply.</p>
<h2>Manuals</h2>
<div class="sdm_download_button_box_default"><div class="sdm_download_link"><a href="https://www.jinpinlub.com/?sdm_process_download=1&download_id=3664" class="sdm_download white" title="Private: VSL-KR Distributor" target=&quot;_blank&quot;>View Datasheet - VSL-KR Distributor</a></div></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>VSKV-KR Metering Valves For Dual Line Lubrication Systems</title>
		<link>https://www.jinpinlub.com/product/vskv-kr-metering-valves-for-dual-line-lubrication-systems/</link>
		
		<dc:creator><![CDATA[JINPINLUB]]></dc:creator>
		<pubDate>Fri, 13 Sep 2024 15:48:18 +0000</pubDate>
				<guid isPermaLink="false">https://www.jinpinlub.com/?post_type=product&#038;p=3680</guid>

					<description><![CDATA[VSKV-KR metering valves are designed for dual-line lubrication systems and are suitable for use in industrial applications such as cement plants, mining excavators and steel mills. They are made of galvanized steel, can withstand pressures up to 400 bar.]]></description>
										<content:encoded><![CDATA[<h2>Feature</h2>
<p>The front of VSKV-KR dual line distributor is equipped with upper and lower discharge ports. When the distributor piston moves in both directions, grease is discharged from the upper and lower ports respectively. The working condition of the distributor can also be directly observed from the action of the indicator rod, outlet flow rate can be adjusted within the specified range by adjusting the screw.<br />
VSKV-KR is suitable for a 40 MPa dual line grease centralized lubrication system. Under the alternating pressure of two main lines, it controls the piston to move and discharge, and distributes lubricant quantitatively to lubrication points.</p>
<h2>Specification</h2>
<table>
<tbody>
<tr>
<td>Model</td>
<td>VSKV-KR</td>
</tr>
<tr>
<td>Operating pressure</td>
<td>40 MPa</td>
</tr>
<tr>
<td>Action pressure</td>
<td>≤1.5 MPa</td>
</tr>
<tr>
<td>Rated discharge</td>
<td>0 ~ 1.5 mL/cyc</td>
</tr>
<tr>
<td>Adjusting screw flow</td>
<td>0.05mL/circle</td>
</tr>
<tr>
<td>Number of outlets</td>
<td>2~8</td>
</tr>
<tr>
<td>Lubricant</td>
<td>Grease NLGI 0~2# or Oil ＞ N68</td>
</tr>
<tr>
<td>Operating temperature</td>
<td>(-10 ℃ ~ 80 ℃)</td>
</tr>
</tbody>
</table>
<h2>Application</h2>
<p>Cement Plant: During cement production, the lubrication of the VSKV-KR distributor ensures smooth operation of the machine and reduces wear.<br />
Mining Excavator: Mining equipment usually works in harsh environments, and the lubrication system of the VSKV-KR metering valve can extend the service life of the equipment.<br />
Steel Plant: Steel production equipment needs to operate under high temperature and high pressure, and the VSKV-KR divider can provide precise lubrication to ensure efficient operation of the equipment.</p>
<h2>Manuals</h2>
<div class="sdm_download_button_box_default"><div class="sdm_download_link"><a href="https://www.jinpinlub.com/?sdm_process_download=1&download_id=3663" class="sdm_download white" title="Private: VSKV-KR Distributor" target=&quot;_blank&quot;>View Datasheet - VSKV-KR Distributor</a></div></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DV-H ZVC Metering Valves For Dual Line Lubrication Systems</title>
		<link>https://www.jinpinlub.com/product/dv-h-zvc-metering-valves-for-dual-line-lubrication-systems/</link>
		
		<dc:creator><![CDATA[JINPINLUB]]></dc:creator>
		<pubDate>Fri, 13 Sep 2024 12:22:46 +0000</pubDate>
				<guid isPermaLink="false">https://www.jinpinlub.com/?post_type=product&#038;p=3671</guid>

					<description><![CDATA[ZV-C dual-line distributor is used in dual-line centralized lubrication system, which can quantitatively distribute lubricating grease to each lubrication point. It is suitable for manufacturing, steel, mining, papermaking and chemical industries. The discharge is adjustable.]]></description>
										<content:encoded><![CDATA[<h2>Feature</h2>
<p>Suitable for 20MPa dual line centralized lubrication systems. It drives the piston to output lubricant under the alternating oil supply pressure of two oil supply pipes, completing the quantitative distribution of lubricant.<br />
DV-H outlets are all at the bottom, and the distributor piston moves forward and backward from the same outlet for output. Every time the system works, each outlet is outputed once.<br />
Operation of DV-H can be directly observed from indicator, and the output volume of each outlet can be adjusted within the specified range by adjusting the screws.</p>
<h2>Specification</h2>
<figure id="attachment_3672" aria-describedby="caption-attachment-3672" style="width: 900px" class="wp-caption alignnone"><img fetchpriority="high" decoding="async" class="size-full wp-image-3672" src="https://www.jinpinlub.com/wp-content/uploads/2024/09/DV-H-Specification.jpg" alt="DV-H Specification" width="900" height="660" srcset="https://www.jinpinlub.com/wp-content/uploads/2024/09/DV-H-Specification.jpg 900w, https://www.jinpinlub.com/wp-content/uploads/2024/09/DV-H-Specification-300x220.jpg 300w, https://www.jinpinlub.com/wp-content/uploads/2024/09/DV-H-Specification-768x563.jpg 768w, https://www.jinpinlub.com/wp-content/uploads/2024/09/DV-H-Specification-16x12.jpg 16w, https://www.jinpinlub.com/wp-content/uploads/2024/09/DV-H-Specification-800x587.jpg 800w" sizes="(max-width: 900px) 100vw, 900px" /><figcaption id="caption-attachment-3672" class="wp-caption-text">DV-H Specification</figcaption></figure>
<h2>Application</h2>
<p>Manufacturing industry: ZVC distributors are used in dual-line lubrication systems such as machine tools, die-casting machines and injection molding machines.<br />
Steel industry: ZVC distributors are used in dual-line lubrication systems for rolling mills, continuous casting machines and other equipment.<br />
Mining industry: ZVC dual-line metering valves are used for lubrication of mining machinery and equipment, such as crushers and screening machines.<br />
Papermaking industry: ZVC dual-line metering devices are used for lubrication of papermaking machinery to ensure smooth operation of equipment.<br />
Chemical industry: DV-H distributors are used for lubrication of chemical equipment to prevent equipment wear and corrosion.</p>
<h2>Manuals</h2>
<div class="sdm_download_button_box_default"><div class="sdm_download_link"><a href="https://www.jinpinlub.com/?sdm_process_download=1&download_id=3656" class="sdm_download white" title="Private: DV-H Dual-line Distributor" target=&quot;_blank&quot;>View Datasheet - DV-H Distributor</a></div></div>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
