<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>JINPUINLUB lubrication pump &#8211; JINPINLUB</title>
	<atom:link href="https://www.jinpinlub.com/product-tag/jinpuinlub-lubrication-pump/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.jinpinlub.com</link>
	<description>Lubrication system solution provider</description>
	<lastBuildDate>Thu, 12 Dec 2024 21:49:16 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://www.jinpinlub.com/wp-content/uploads/2024/08/JINPINLUB-100x100.png</url>
	<title>JINPUINLUB lubrication pump &#8211; JINPINLUB</title>
	<link>https://www.jinpinlub.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>J200 Detachable Precision Lubrication Pump for Grinding CNC</title>
		<link>https://www.jinpinlub.com/product/j200-detachable-precision-lubrication-pump-for-grinding-cnc/</link>
		
		<dc:creator><![CDATA[JINPINLUB]]></dc:creator>
		<pubDate>Thu, 12 Dec 2024 21:32:23 +0000</pubDate>
				<guid isPermaLink="false">https://www.jinpinlub.com/?post_type=product&#038;p=4028</guid>

					<description><![CDATA[Jinpinlub J200 is a high-performance lubrication pump. Its flow is precise, the structural design is exquisite and compact, the installation is convenient, and it is suitable for various device spaces. Extremely low noise during operation, creating a quiet working environment.]]></description>
										<content:encoded><![CDATA[<h2>Features</h2>
<p>Level switch function<br />
The level switch is integrated inside the J200 lubrication pump. When the level switch is activated, the pump can be stopped before the grease is completely exhausted, effectively preventing air from mixing into the grease and ensuring the normal operation of the lubrication system.<br />
Working condition restrictions<br />
The level switch only outputs a signal when the J200 lubrication pump is powered on. Since the pump stops when the level switch is activated, this may cause the pressure switch to not work properly and output an abnormal pressure signal.<br />
Operation precautions<br />
The level switch and the filter adapter form an integral unit. When the empty cartridge is removed, the abnormal output on the device side remains. If the power is turned on in this case, the J200 lubrication pump will inhale air. Therefore, be sure to insert a new cartridge before turning the power back on and release the abnormal output.</p>
<h2>Specification</h2>
<table>
<tbody>
<tr>
<td>Model</td>
<td>J200-5D</td>
</tr>
<tr>
<td>Lubrication time</td>
<td>PLC or external controller</td>
</tr>
<tr>
<td>Interval time</td>
<td>PLC or external controller</td>
</tr>
<tr>
<td>Operating temperature</td>
<td>0℃~ +50°C (Low temperature conditions require antifreeze grease)</td>
</tr>
<tr>
<td>Number of outlets</td>
<td>1 or 2</td>
</tr>
<tr>
<td>Reservoir capacity</td>
<td>0.3L, 0.5L, 0.7L</td>
</tr>
<tr>
<td>Refilling</td>
<td>Removable reservoir/cartridge</td>
</tr>
<tr>
<td>Lubricant</td>
<td>Greases NLGI grade 000~2#</td>
</tr>
<tr>
<td>Pressure relief valve</td>
<td>Assembled</td>
</tr>
<tr>
<td>Discharge</td>
<td>7 mL/min</td>
</tr>
<tr>
<td>Max. operating pressure</td>
<td>5.0 or 8.0 MPa</td>
</tr>
<tr>
<td>Connection thread</td>
<td>Outlet Φ6</td>
</tr>
<tr>
<td>Operating voltage</td>
<td>24VDC</td>
</tr>
<tr>
<td>Certification</td>
<td>CE</td>
</tr>
<tr>
<td>Low level switch</td>
<td>N.C. contact</td>
</tr>
</tbody>
</table>
<h2>Pipeline</h2>
<p>1. Connection steps<br />
Connect the pipe to the outlet of the lubrication pump. Use a pipe with a pressure resistance of 10MPa or higher. First, manually fix the joint to ensure the initial stability of the connection. Then tighten it with a wrench. Pay attention to the moderate strength of this operation. The appropriate torque is 7.1N･m.<br />
2. Check after connection<br />
After the connection is completed, be sure to carefully check whether there is grease leakage at the joint to ensure the sealing of the connection. Then, exhaust the air to remove the air that may exist in the pipe and lubrication pump.<br />
3. Pressure situation description<br />
Although 8MPa or higher pressure may occur when the main pipeline is short, it will not cause problems under normal use, but it is still necessary to pay attention to the pressure changes of the lubrication system to ensure that it is within the normal working range.</p>
<h2>Manuals</h2>
<div class="sdm_download_button_box_default"><div class="sdm_download_link"><a href="https://www.jinpinlub.com/?sdm_process_download=1&download_id=3962" class="sdm_download white" title="Private: J200 Electric Pump" target=&quot;_blank&quot;>View Datasheet - J200 Grease Pump</a></div></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Jinpinlub J200 CNC Lubrication Pump For LHL Grease Cartridge</title>
		<link>https://www.jinpinlub.com/product/jinpinlub-j200-cnc-lubrication-pump-for-lhl-grease-cartridge/</link>
		
		<dc:creator><![CDATA[JINPINLUB]]></dc:creator>
		<pubDate>Thu, 12 Dec 2024 20:49:24 +0000</pubDate>
				<guid isPermaLink="false">https://www.jinpinlub.com/?post_type=product&#038;p=4023</guid>

					<description><![CDATA[Jinpinlub J200 lubrication pump is a small electric grease pump with the functions of convenient refilling, automatic detection of system pressure, automatic control of running time and interval time, and automatic pressure relief. It is small in size, reliable in operation.]]></description>
										<content:encoded><![CDATA[<h2>Features</h2>
<p><span id="input-sentence~0">&#8211; Operating pressure of this J200 lubrication pump is within the range of 5MPa to 8MPa, which provides stable high-pressure delivery of lubricant.<br />
&#8211; The lubricant output from the lubrication pump is 7 ml per minute. This stable discharge helps for efficient operation of the lubrication system.</span><span id="input-sentence~1"><br />
&#8211; The J20 lubrication pump has an IP54 protection rating, which means it has good dust and water resistance and can operate reliably in dusty and humid environments.<br />
&#8211; The lubrication pump uses a DC 24V power supply. This design not only ensures the efficient operation of the pump, but also saves energy.<br />
&#8211; The lubrication pump is equipped with an optional feed switch and lubricant level switch for user monitoring and operation. In addition, a specific removable grease cartridge is used.</span></p>
<h2>Specification</h2>
<table>
<tbody>
<tr>
<td>Model</td>
<td>J200-3D</td>
</tr>
<tr>
<td>Lubrication time</td>
<td>PLC or external controller</td>
</tr>
<tr>
<td>Interval time</td>
<td>PLC or external controller</td>
</tr>
<tr>
<td>Operating temperature</td>
<td>0℃~ +50°C (Low temperature conditions require antifreeze grease)</td>
</tr>
<tr>
<td>Number of outlets</td>
<td>1 or 2</td>
</tr>
<tr>
<td>Reservoir capacity</td>
<td>0.3L, 0.5L, 0.7L</td>
</tr>
<tr>
<td>Refilling</td>
<td>Removable reservoir/cartridge</td>
</tr>
<tr>
<td>Lubricant</td>
<td>Greases NLGI grade 000~2#</td>
</tr>
<tr>
<td>Pressure relief valve</td>
<td>Assembled</td>
</tr>
<tr>
<td>Discharge</td>
<td>7 mL/min</td>
</tr>
<tr>
<td>Max. operating pressure</td>
<td>5.0 or 8.0 MPa</td>
</tr>
<tr>
<td>Connection thread</td>
<td>Outlet Φ6</td>
</tr>
<tr>
<td>Operating voltage</td>
<td>24VDC</td>
</tr>
<tr>
<td>Certification</td>
<td>CE</td>
</tr>
<tr>
<td>Low level switch</td>
<td>N.C. contact</td>
</tr>
</tbody>
</table>
<h2>Refilling</h2>
<p>&#8211; If the lubrication pump does not discharge grease, there may be less grease remaining in the reservoir. If the valve does not discharge, the valve may be blocked.<br />
&#8211; If there is air in the lubrication pump, exhaust it according to the instructions in the user manual. If there is air in the main pipeline, remove the end plug and operate the pump to exhaust.<br />
&#8211; If the lubrication pump does not run, check the 24VDC power connection to ensure that the positive and negative poles of the wires are connected correctly. Even if the polarity is wrong, the pump will not be damaged, but it needs to be corrected.<br />
&#8211; If the lubrication pump discharges low pressure, there may be leakage at the pump outlet or the machine pipeline connection parts. If the pipeline is damaged, it needs to be replaced.<br />
&#8211; If the main pipeline pressure is not established, refer to the treatment of the lubrication pump not discharging grease. It may also be a power outage, pipeline damage or air in the system.</p>
<h2>Manuals</h2>