<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>machine tool lubrication pump &#8211; JINPINLUB</title>
	<atom:link href="https://www.jinpinlub.com/product-tag/machine-tool-lubrication-pump/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.jinpinlub.com</link>
	<description>Lubrication system solution provider</description>
	<lastBuildDate>Thu, 12 Dec 2024 21:49:09 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.jinpinlub.com/wp-content/uploads/2024/08/JINPINLUB-100x100.png</url>
	<title>machine tool lubrication pump &#8211; JINPINLUB</title>
	<link>https://www.jinpinlub.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>J200-5D Electric Lubrication Pump With Detachable Reservoir</title>
		<link>https://www.jinpinlub.com/product/j200-5d-electric-lubrication-pump-with-detachable-reservoir/</link>
		
		<dc:creator><![CDATA[JINPINLUB]]></dc:creator>
		<pubDate>Thu, 12 Dec 2024 15:27:32 +0000</pubDate>
				<guid isPermaLink="false">https://www.jinpinlub.com/?post_type=product&#038;p=4018</guid>

					<description><![CDATA[J200 is an electric lubrication pump, a single-line lubrication system pump unit. Its key features include: power supply is DC24V, discharge volume is 7ml per minute, discharge pressure is 5MPa to 8MPa, suitable for lithium-based grease, IP54 protection grade.]]></description>
										<content:encoded><![CDATA[<h2>Features</h2>
<p><span id="input-sentence~0">1. Power supply and start-up<br />
The lubrication pump is powered by a 24V DC power supply. When the power is turned on, the motor starts. The rated current of the motor is 0.8A. Within the normal power supply range, the motor can run stably and provide power for the pump.</span><span id="input-sentence~1"><br />
2. Lubricant delivery<br />
The motor drives the lubrication pump to work. The lubricant is extracted from the storage container or cartridge through the internal structure including the plunger, gears, etc., and is delivered to each lubrication point of the machine through the pipeline at a displacement of 7ml/min.</span><span id="input-sentence~2"> During the delivery process, the discharge pressure can reach 8MPa.<br />
3. Metering and control<br />
In the lubrication system, the positive displacement distributor is used for precise control over the amount of lubricant to be delivered. This enables each lubrication point to acquire an appropriate amount of lubricant in order to achieve an optimized lubrication effect, rather than wasting lubricants. The running time and interval cycle of the lubrication pump are set by the timer installed on the machine and work under program setup.</span></p>
<h2>Specification</h2>
<table>
<tbody>
<tr>
<td>Model</td>
<td>J200-5D</td>
</tr>
<tr>
<td>Lubrication time</td>
<td>PLC or external controller</td>
</tr>
<tr>
<td>Interval time</td>
<td>PLC or external controller</td>
</tr>
<tr>
<td>Operating temperature</td>
<td>0℃~ +50°C (Low temperature conditions require antifreeze grease)</td>
</tr>
<tr>
<td>Number of outlets</td>
<td>1 or 2</td>
</tr>
<tr>
<td>Reservoir capacity</td>
<td>0.3L, 0.5L, 0.7L</td>
</tr>
<tr>
<td>Refilling</td>
<td>Removable reservoir/cartridge</td>
</tr>
<tr>
<td>Lubricant</td>
<td>Greases NLGI grade 000~2#</td>
</tr>
<tr>
<td>Pressure relief valve</td>
<td>Assembled</td>
</tr>
<tr>
<td>Discharge</td>
<td>7 mL/min</td>
</tr>
<tr>
<td>Max. operating pressure</td>
<td>5.0 or 8.0 MPa</td>
</tr>
<tr>
<td>Connection thread</td>
<td>Outlet Φ6</td>
</tr>
<tr>
<td>Operating voltage</td>
<td>24VDC</td>
</tr>
<tr>
<td>Certification</td>
<td>CE</td>
</tr>
<tr>
<td>Low level switch</td>
<td>N.C. contact</td>
</tr>
</tbody>
</table>
<h2>Refilling</h2>
<p><span id="input-sentence~0">&#8211; Replace the cartridge after the LHL in the cartridge is completely exhausted to avoid air entering the cartridge due to residual grease, which may cause malfunctioning of the lubrication pump.<br />
&#8211; During the process of replacement of the cartridge, make sure that the surroundings are clean to avoid foreign objects like dust and impurities entering the lubrication pump body or cartridge.</span><span id="input-sentence~1"><br />
&#8211; It is strictly forbidden to turn on the power when the cartridge is not installed in place or removed, otherwise the lubrication pump may inhale air or foreign objects.<br />
&#8211; When replacing the cartridge, if you need to wipe around the oil suction port of the pump, you must use a clean cloth to prevent foreign objects from being sucked into the lubrication pump.<br />
&#8211; Only use the specified LHL grease cartridge. Using other non-specified lubricants may cause lubrication system failure.<br />
&#8211; Never fill the used empty grease cartridge with lubricant and use it again.</span></p>
<h2>Manuals</h2>
<div class="sdm_download_button_box_default"><div class="sdm_download_link"><a href="https://www.jinpinlub.com/?sdm_process_download=1&download_id=3962" class="sdm_download white" title="Private: J200 Electric Pump" target=&quot;_blank&quot;>View Datasheet - J200 Grease Pump</a></div></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>J200-3R Single-Line Lubrication Pump For Precise Lubrication</title>
		<link>https://www.jinpinlub.com/product/j200-3r-single-line-lubrication-pump-for-precise-lubrication/</link>
		
		<dc:creator><![CDATA[JINPINLUB]]></dc:creator>
		<pubDate>Thu, 12 Dec 2024 09:45:07 +0000</pubDate>
				<guid isPermaLink="false">https://www.jinpinlub.com/?post_type=product&#038;p=4013</guid>

					<description><![CDATA[J200 is a highly efficient lubrication device with features including: DC24V power supply, 7ml/min discharge volume and 5-8MPa discharge pressure. It is suitable for a variety of industrial applications to ensure long-term stable operation of the equipment.]]></description>
										<content:encoded><![CDATA[<h2>Features</h2>
<p>&#8211; Precise lubrication delivery: precise delivery of small amounts of lubricant is achieved through metering valves to ensure precise lubrication of each lubrication point of the machine.<br />
&#8211; Liquid level switch: integrated in the cartridge adapter, it can stop the pump in time when the cartridge is out of oil, effectively prevent air from mixing into the lubrication system and ensure lubrication effect.<br />
&#8211; Easy cartridge replacement: it needs to be carried out according to the steps, such as rotating to remove the old cartridge, installing the new cartridge and tightening the cover.<br />
&#8211; Removable reservoir: optional removable reservoir version, no need to replace the cartridge to achieve simple repeated grease filling.<br />
&#8211; Strong environmental adaptability: it can work under ambient temperature 0 &#8211; 50°C and humidity 35 &#8211; 85%RH, and the vibration requirement is below 9G (88m/s²), which can resist the influence of adverse environmental factors such as water, oil, debris, dust, etc. to a certain extent.</p>
<h2>Specification</h2>
<table>
<tbody>
<tr>
<td>Model</td>
<td>J200-3D</td>
</tr>
<tr>
<td>Lubrication time</td>
<td>PLC or external controller</td>
</tr>
<tr>
<td>Interval time</td>
<td>PLC or external controller</td>
</tr>
<tr>
<td>Operating temperature</td>
<td>0℃~ +50°C (Low temperature conditions require antifreeze grease)</td>
</tr>
<tr>
<td>Number of outlets</td>
<td>1 or 2</td>
</tr>
<tr>
<td>Reservoir capacity</td>
<td>0.3L, 0.5L, 0.7L</td>
</tr>
<tr>
<td>Refilling</td>
<td>Removable reservoir/cartridge</td>
</tr>
<tr>
<td>Lubricant</td>
<td>Greases NLGI grade 000~2#</td>
</tr>
<tr>
<td>Pressure relief valve</td>
<td>Assembled</td>
</tr>
<tr>
<td>Discharge</td>
<td>7 mL/min</td>
</tr>
<tr>
<td>Max. operating pressure</td>
<td>5.0 or 8.0 MPa</td>
</tr>
<tr>
<td>Connection thread</td>
<td>Outlet Φ6</td>
</tr>
<tr>
<td>Operating voltage</td>
<td>24VDC</td>
</tr>
<tr>
<td>Certification</td>
<td>CE</td>
</tr>
<tr>
<td>Low level switch</td>
<td>N.C. contact</td>
</tr>
</tbody>
</table>
<h2>Wiring</h2>
<p><span id="input-sentence~0">&#8211; Personnel qualifications: The wiring of the lubrication pump should be done by personnel qualified to do electrical work to ensure that the wiring is appropriate and safe.<br />
&#8211; Polarity confirmation: The motor has polarity. In connecting the (+) and (-) wires, one should refer to the diagram for careful confirmation to avoid equipment failure due to incorrect polarity.</span><span id="input-sentence~1"><br />
&#8211; Insulation measures: If the wires from the 24VDC power supply may contact the lubrication pump body, human body or surrounding objects, insulated wires must be used to prevent leakage and electric shock accidents.<br />
&#8211; Ground connection: Connect the ground wire to the designated component to prevent leakage and electric shock. At the same time, to prevent fire caused by overcurrent, pay attention to the current limit. If the current exceeds 1.2A, the internal drive mechanism of the lubrication pump will return to the initial position.</span></p>