<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Minimum quantity lubrication &#8211; JINPINLUB</title>
	<atom:link href="https://www.jinpinlub.com/product-tag/minimum-quantity-lubrication/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.jinpinlub.com</link>
	<description>Lubrication system solution provider</description>
	<lastBuildDate>Wed, 01 Jan 2025 16:29:16 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.jinpinlub.com/wp-content/uploads/2024/08/JINPINLUB-100x100.png</url>
	<title>Minimum quantity lubrication &#8211; JINPINLUB</title>
	<link>https://www.jinpinlub.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>MLS 4L Minimal Lubrication Control Unit For Sawing Machine</title>
		<link>https://www.jinpinlub.com/product/mls-0-5l-minimal-lubrication-control-unit-for-sawing-machine/</link>
		
		<dc:creator><![CDATA[JINPINLUB]]></dc:creator>
		<pubDate>Wed, 01 Jan 2025 13:06:51 +0000</pubDate>
				<guid isPermaLink="false">https://www.jinpinlub.com/?post_type=product&#038;p=4052</guid>

					<description><![CDATA[MLS micro lubrication system adopts a positive displacement pump powered by compressed air, which can accurately control the output of oil mist. It features modular design, reliable performance, flexible configuration, and easy installation.]]></description>
										<content:encoded><![CDATA[<h2>Feature</h2>
<p>1. Precision lubrication: micro-lubrication pump has good adjustability, air metering screw, and pump stroke adjustment knob that accurately control the spray volume of the atomizing pump; pulse generator controlling the pump cycle rate can be conducted in several kinds of precise adjustment ways.<br />
2. Flexibility in configuration: It is a modular design that customers can configure themselves according to their needs. The system consists of all kinds of pumps, regulating valves, liquid storage tanks, and so on. Different application scenes are adopted with different system structures and component collocations.<br />
3. The parameters are determined: air supply pressure, micro-lubrication pump parameter, air flow, pulse generator frequency, working and storage temperature range, etc.</p>
<h2>Specification</h2>
<table>
<tbody>
<tr>
<td>Supply air pressure</td>
<td>Clean, dry compressed air, 4~7 bar, 708 LPM minimum</td>
</tr>
<tr>
<td>Pump viscosity</td>
<td>50~1000 SUS</td>
</tr>
<tr>
<td>Pump output at full stroke</td>
<td>0.033mL (1-drop standard), 0.100mL (3-drop standard)</td>
</tr>
<tr>
<td>Pump output rate</td>
<td>0~396mL/hr (1-drop standard), 0~1200mL/hr (3-drop standard)</td>
</tr>
<tr>
<td>Air flow rate</td>
<td>0~4 SCFM for each air and oil output, 1~2 SCFM typical</td>
</tr>
<tr>
<td>Pulse generator</td>
<td>5~50 pulses/min, Max 200pulses/min(not recommended)</td>
</tr>
<tr>
<td>Operating temperature</td>
<td>0℃ ~ +50˚C</td>
</tr>
<tr>
<td>Storage temperature</td>
<td>(-16℃ ~ +70˚C)</td>
</tr>
<tr>
<td>Fluid reservoir</td>
<td>Customizable, standard 0.5L, 1.0L, 2L, 4L</td>
</tr>
</tbody>
</table>
<h2><span data-slate-fragment="JTVCJTdCJTIydHlwZSUyMiUzQSUyMnBhcmFncmFwaCUyMiUyQyUyMmNoaWxkcmVuJTIyJTNBJTVCJTdCJTIyaWQlMjIlM0ElMjJXUDU4YUw0Snc3JTIyJTJDJTIycGFyYUlkeCUyMiUzQTAlMkMlMjJzcmMlMjIlM0ElMjJtYWludGVuYW5jZSUyMiUyQyUyMmRzdCUyMiUzQSUyMiVFNyVCQiVCNCVFNCVCRiVBRSUyMiUyQyUyMm1ldGFkYXRhJTIyJTNBJTIyJTIyJTJDJTIybWV0YURhdGElMjIlM0ElNUIlNUQlMkMlMjJ0ZXh0JTIyJTNBJTIybWFpbnRlbmFuY2UlMjIlN0QlNUQlN0QlNUQ=">Mounting</span></h2>
<p><span id="input-sentence~0">Installation location<br />
The micro lubrication system is installed near the machine and ensures that there are no obstacles that may compress or twist the output or gas supply pipelines. Meanwhile, the device must be installed with the storage tank facing upwards and in a horizontal position.</span><span id="input-sentence~1"><br />
Installation method<br />
Direct installation: Directly mount the micro lubrication system onto the machine, observing the installation for personal safety. Use appropriate screws at each of the installation positions with their corresponding screws for correct installation.<br />
Magnet installation: Installation with magnets may also be optionally used depending on where installation requirements need. Observing safety in the installation will also ensure the stability of the micro lubrication system being installed.</span></p>
<h2>Manuals</h2>
<div class="sdm_download_button_box_default"><div class="sdm_download_link"><a href="https://www.jinpinlub.com/?sdm_process_download=1&download_id=4054" class="sdm_download white" title="Private: Minimal Quantity Lubrication" target=&quot;_blank&quot;>View Datasheet - Minimal Quantity Lubrication</a></div></div>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>