<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Oil mist Coolant Pumps &#8211; JINPINLUB</title>
	<atom:link href="https://www.jinpinlub.com/product-tag/oil-mist-coolant-pumps/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.jinpinlub.com</link>
	<description>Lubrication system solution provider</description>
	<lastBuildDate>Sat, 11 Jan 2025 03:48:58 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://www.jinpinlub.com/wp-content/uploads/2024/08/JINPINLUB-100x100.png</url>
	<title>Oil mist Coolant Pumps &#8211; JINPINLUB</title>
	<link>https://www.jinpinlub.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Micro Precision Spray Lubrication System For Metal Cutting</title>
		<link>https://www.jinpinlub.com/product/micro-precision-spray-lubrication-system-for-metal-cutting/</link>
		
		<dc:creator><![CDATA[JINPINLUB]]></dc:creator>
		<pubDate>Wed, 01 Jan 2025 17:03:48 +0000</pubDate>
				<guid isPermaLink="false">https://www.jinpinlub.com/?post_type=product&#038;p=4065</guid>

					<description><![CDATA[MLS micro-lubrication pump is a device used to replace the traditional water-soluble cutting fluid cooling system. It sprays a mixture of air and oil into the processing area through high-pressure atomization, so that a small amount of lubricating oil is more evenly dispersed.]]></description>
										<content:encoded><![CDATA[<h2>Feature</h2>
<p><span id="input-sentence~0">&#8211; Air and oil mixture: minimum quantity lubrication pump can provide a mixture of air and oil that may be used for different application scenarios requiring precise lubrication.<br />
&#8211; Adjustment function: Stroke regulator and pulse generator in minimum quantity lubrication pump allow users to regulate the circulation rate and output per stroke of the pump according to requirement, hence accurate regulation.</span><span id="input-sentence~1"><br />
<span id="input-sentence~0">&#8211; </span>Environmentally friendly: The ISO VG 68 machine tool guide oil recommended by the pump has environmentally friendly characteristics, and precise micro-oil mist lubrication can further reduce the impact on the environment.<br />
<span id="input-sentence~0">&#8211; </span>High-performance materials: Nozzles of different materials are suitable for different working environments, such as stainless steel nozzles for environments that require high rigidity, while flexible plastic nozzles are suitable for environments that require easy adjustment of direction.</span></p>
<h2>Specification</h2>
<table>
<tbody>
<tr>
<td>Supply air pressure</td>
<td>Clean, dry compressed air, 4~7 bar, 708 LPM minimum</td>
</tr>
<tr>
<td>Pump viscosity</td>
<td>50~1000 SUS</td>
</tr>
<tr>
<td>Pump output at full stroke</td>
<td>0.033mL (1-drop standard), 0.100mL (3-drop standard)</td>
</tr>
<tr>
<td>Pump output rate</td>
<td>0~396mL/hr (1-drop standard), 0~1200mL/hr (3-drop standard)</td>
</tr>
<tr>
<td>Air flow rate</td>
<td>0~4 SCFM for each air and oil output, 1~2 SCFM typical</td>
</tr>
<tr>
<td>Pulse generator</td>
<td>5~50 pulses/min, Max 200pulses/min(not recommended)</td>
</tr>
<tr>
<td>Operating temperature</td>
<td>0℃ ~ +50˚C</td>
</tr>
<tr>
<td>Storage temperature</td>
<td>(-16℃ ~ +70˚C)</td>
</tr>
<tr>
<td>Fluid reservoir</td>
<td>Customizable, standard 0.5L, 1.0L, 2L, 4L</td>
</tr>
</tbody>
</table>
<h2>Mounting</h2>
<p><span id="input-sentence~0">1. Installation preparation: Read the operational manual, understand the principles of the minimal quantity lubrication system, component functions, and adjustment methods. Prepare all the tools which may be required for mounting.<br />
2. Installation location: Choose a place close to the machine and easy for operation and maintenance, making sure the minimal quantity lubrication pump is installed horizontally with the liquid storage tank up.</span><span id="input-sentence~1"><br />
3. Installation method: Fixed by screws at four installation places minimum quantity lubrication system. As for the case magnet installation method is adopted, it needs to be installed in clean and flat installment location.<br />
4. Air connection: Keep the air supply pressure between 4 -7 bar, connect the air supply line through the air filter, and seal the interface.<br />
5. Thin oil filling: Fill in the qualified thin oil to 75% of the volume of the oil tank. In the process of filling, push down the cover to discharge extra air.</span></p>
<h2>Manuals</h2>
<div class="sdm_download_button_box_default"><div class="sdm_download_link"><a href="https://www.jinpinlub.com/?sdm_process_download=1&download_id=4054" class="sdm_download white" title="Private: Minimal Quantity Lubrication" target=&quot;_blank&quot;>View Datasheet - Minimal Quantity Lubrication</a></div></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MLS 4L Minimal Lubrication Control Unit For Sawing Machine</title>
		<link>https://www.jinpinlub.com/product/mls-0-5l-minimal-lubrication-control-unit-for-sawing-machine/</link>
		
		<dc:creator><![CDATA[JINPINLUB]]></dc:creator>
		<pubDate>Wed, 01 Jan 2025 13:06:51 +0000</pubDate>
				<guid isPermaLink="false">https://www.jinpinlub.com/?post_type=product&#038;p=4052</guid>

					<description><![CDATA[MLS micro lubrication system adopts a positive displacement pump powered by compressed air, which can accurately control the output of oil mist. It features modular design, reliable performance, flexible configuration, and easy installation.]]></description>
										<content:encoded><![CDATA[<h2>Feature</h2>
<p>1. Precision lubrication: micro-lubrication pump has good adjustability, air metering screw, and pump stroke adjustment knob that accurately control the spray volume of the atomizing pump; pulse generator controlling the pump cycle rate can be conducted in several kinds of precise adjustment ways.<br />
2. Flexibility in configuration: It is a modular design that customers can configure themselves according to their needs. The system consists of all kinds of pumps, regulating valves, liquid storage tanks, and so on. Different application scenes are adopted with different system structures and component collocations.<br />
3. The parameters are determined: air supply pressure, micro-lubrication pump parameter, air flow, pulse generator frequency, working and storage temperature range, etc.</p>
<h2>Specification</h2>
<table>
<tbody>
<tr>
<td>Supply air pressure</td>
<td>Clean, dry compressed air, 4~7 bar, 708 LPM minimum</td>
</tr>
<tr>
<td>Pump viscosity</td>
<td>50~1000 SUS</td>
</tr>
<tr>
<td>Pump output at full stroke</td>
<td>0.033mL (1-drop standard), 0.100mL (3-drop standard)</td>
</tr>
<tr>
<td>Pump output rate</td>
<td>0~396mL/hr (1-drop standard), 0~1200mL/hr (3-drop standard)</td>
</tr>
<tr>
<td>Air flow rate</td>
<td>0~4 SCFM for each air and oil output, 1~2 SCFM typical</td>
</tr>
<tr>
<td>Pulse generator</td>
<td>5~50 pulses/min, Max 200pulses/min(not recommended)</td>
</tr>
<tr>
<td>Operating temperature</td>
<td>0℃ ~ +50˚C</td>
</tr>
<tr>
<td>Storage temperature</td>
<td>(-16℃ ~ +70˚C)</td>
</tr>
<tr>
<td>Fluid reservoir</td>
<td>Customizable, standard 0.5L, 1.0L, 2L, 4L</td>
</tr>
</tbody>
</table>
<h2><span data-slate-fragment="JTVCJTdCJTIydHlwZSUyMiUzQSUyMnBhcmFncmFwaCUyMiUyQyUyMmNoaWxkcmVuJTIyJTNBJTVCJTdCJTIyaWQlMjIlM0ElMjJXUDU4YUw0Snc3JTIyJTJDJTIycGFyYUlkeCUyMiUzQTAlMkMlMjJzcmMlMjIlM0ElMjJtYWludGVuYW5jZSUyMiUyQyUyMmRzdCUyMiUzQSUyMiVFNyVCQiVCNCVFNCVCRiVBRSUyMiUyQyUyMm1ldGFkYXRhJTIyJTNBJTIyJTIyJTJDJTIybWV0YURhdGElMjIlM0ElNUIlNUQlMkMlMjJ0ZXh0JTIyJTNBJTIybWFpbnRlbmFuY2UlMjIlN0QlNUQlN0QlNUQ=">Mounting</span></h2>
<p><span id="input-sentence~0">Installation location<br />
The micro lubrication system is installed near the machine and ensures that there are no obstacles that may compress or twist the output or gas supply pipelines. Meanwhile, the device must be installed with the storage tank facing upwards and in a horizontal position.</span><span id="input-sentence~1"><br />
Installation method<br />
Direct installation: Directly mount the micro lubrication system onto the machine, observing the installation for personal safety. Use appropriate screws at each of the installation positions with their corresponding screws for correct installation.<br />
Magnet installation: Installation with magnets may also be optionally used depending on where installation requirements need. Observing safety in the installation will also ensure the stability of the micro lubrication system being installed.</span></p>
<h2>Manuals</h2>
<div class="sdm_download_button_box_default"><div class="sdm_download_link"><a href="https://www.jinpinlub.com/?sdm_process_download=1&download_id=4054" class="sdm_download white" title="Private: Minimal Quantity Lubrication" target=&quot;_blank&quot;>View Datasheet - Minimal Quantity Lubrication</a></div></div>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>